Cracking of underground welded steel pipes caused by HAZ sensitization

An article on case study, published in « Case Studies in Engineering Failure Analysis« , on january 2013.

Low alloy steel welded pipes buried in the ground were sent for failure analysis investigation. Failure of steel pipes was not caused by tensile ductile overload but resulted from low ductility fracture in the area of the weld, which also contains multiple intergranular secondary cracks. The failure is most probably attributed to intergranular cracking initiating from the outer surface in the weld heat affected zone and propagated through the wall thickness.

Read more ….

Fissuration en service de tubes soudés en acier galvanisé

Un cas concret d’analyse de défaillance rapporté dans Case Studies in Engineering Failure Analysis de janvier 2013 concerne la fissuration de tubes en acier soudés et galvanisés servant à l’adduction d’eau de chauffage qui étaient enfouis dans le sol. Pour lire l’article complet cliquez sur le lien :  Cracking of underground welded steel pipes caused by HAZ sensitization.