Fire Truck Fitting Failure

Truck Accidents – Fire Truck Fitting Failure

A cast aluminum alloy « Y » fitting failed during fire hose pressure testing and injured a firefighter. The failed fire trick fitting was submitted for metallurgical failure analysis.

The, as received, knock-on/quick disconnect coupler and failed « Y » are shown in Photograph A.

Overall view of cast aluminum Y fitting.

Photograph A: Overall view of cast aluminum « Y » fitting that failed during fire hose pressure testing.


The casting in question, after apparently 27 years of useful service, failed in a sudden manner. The casting surface did not contain any manufacturer markings, serial numbers, casting lot numbers, etc. which would identify the manufacturer and/or the year of manufacture.

Testing included stereomicroscopic examination, scanning electron microscopy (SEM), metallography, microstructural examination, chemical analysis and hardness testing. Considerable macro and micro-porosity was observed on the primary fracture face. Photograph B illustrates an area of dendrite structure and porosity surrounded by clear indications of cleavagefractures. However, observing shrinkage and the dendrite structure on a casting fracture surface does not render that casting defective. A true and very valid test of adequacy is the performance history of the casting. As time passes and usage increases, the probability of a significant flaw being present diminishes quickly to zero. Additionally, no evidence of progressive fatigue failure was observed on the casting fracture surface or near any area of casting porosity. Fracture features observed where fracture did occur were cleavage, indicating a sudden failure of a casting material lacking in significant ductility. The lack of significant ductility is not uncommon to cast metals.

Photograph B: Scanning electron micrograph showing dendrite casting porosity (rounded egg shaped structure). The yellow arrows denote areas of cleavage fracture occurring during the sudden overpressure failure.

SEM of dendrite casting porosity.

It was determined that the cast metal « Y » fitting failed due to an over-pressurization from an unknown source.

Consumer Product Accidents – Shaft Failure

Consumer Product Accidents – Shaft Failure

Close-up view of failed shaft
Metallurgical failure analysis was requested after a company experienced several identical shaft failures. Macro and microscopic examination revealed that metal bending fatigue was to blame for the failures. The metal fatigue was due to an inadequate filet radius at a diameter change in the subject shaft. The inadequate radius was due to a manufacturing error.

Failure in automotive steering system hydraulic cylinder

www.dtbtest.com/PDFs/steering-system-hydraulic-cylinder-failure.pdf

Description : Failure in automotive steering system hydraulic cylinder
Problem : Piston failures in reduced section transition radius
Analysis : Superimposed stress concentrations due to transition radius and machining marks resulted in circumferential fatigue crack initiation. Was followed by brittle crack propagation due to notch effects.
Resolution & Recommendations :
Modify microstructure from norm. to Q&T and shot peen transition radius to eliminate fatigue crack initiation

Failure in composite wound pressure vessel liner

www.dtbtest.com/PDFs/composite-wound-pressure-vessel-failure.pdf

Description : Failure in composite wound pressure vessel liner
Problem : Spun aluminum alloy (6061-T6) liners failed during first proof pressurization cycle
Analysis : Highly inhomogeneous deformation created local necks and local strains close to fracture strain
Resolution & Recommendations :
Reduce deformation inhomogeneities by refining the grain size in extrusion stock