A failure analysis study on the fractured connecting bolts of a filter press

An interesting case study of failure analysis will be published in Case Studies in Engineering Failure Analysis in October 2015

The purpose of this study was to investigate the main causes of the co-fracture of sixteen connecting bolts of a filter press cylinder–piston system. Stress state of the bolts during the service conditions has been analyzed and the failure reasons were determined from the fractography analysis and gathered information. According to the obtained results, it was concluded that the bolts had failed by the fatigue mechanism. It seems that insufficient torque was used during assembly.

Read more at : A failure analysis study on the fractured connecting bolts of a filter press